BookTitleMAGNET_GENERAL_CATALOG

page
52/186

This page is an overview of MAGNET_GENERAL_CATALOG on page52
Move to the page after second(s).
Now go to the page by clicking "Open the e-Book" button.

MAGNET_GENERAL_CATALOG

ReadBook

Open e-Book in Flash Viewer

This e-Book is not available in your environment.

Open e-Book in HTML5 Viewer

Summary

MAGNET_GENERAL_CATALOG

Model VPU VACUUM SYSTEMVPU-E10VPU-D20・サApplication・スA vacuum system dedicated to the vacuum chucks. The shuck side is evacuated continuouslyin order to eff ectively maintain atmospheric pressure on the workpiece on the chuck work face.Note that this system must not be modifi ed to a pressure container.・サFeatures・ス笳就 vacuum evacuation system, fi lter, vacuum tank and vacuum gage are incorporated neatly.笳輯uction and evacuation operations to mount and demount workpieces can be done quicklyand easily with the attached special operating handle.笳就 diff erence in pressure over 80 kPa (600 mmHg) can be obtained continuously.笆Ejector type VPU-EA vacuum system to reduce pressure by jetting air at high pressure (principle of the spray gun).This is recommended where an air line by use of a compressor is installed. This type can beused for both wet and dry machining operations. However, the use of a lubricator in the air linemust be avoided.笆Dry pump type VPU-DA vacuum system to reduce pressure by evacuation by a pump driven by a motor. A powersource only is required to obtain an independent vacuum source. Note, however, this isrecommended only for dry machining operations.笆Other typesIf the physical contact with the bottom face of workpieces is poor, a large amount of air leaks,requiring a large evacuation amount. In such a case, a blower type is required for dryoperations and a water-sealed vacuum pump is required for wet operations depending on workconditions. Please contact us.笆 Examples of application of vacuumchucks and vacuum systemsChuckPump 1018 1325 1515 1530 1545 2035 2050 3060VPU-E10 笳ッ 笳ッ 笳ッ 笳ッ ・・・・・・・昂PU-E20笳ッ 笳ッ 笳ッ 笳ッ 笳ッ 笳ッ 笳ッ 笳ッVPU-D20笆Ejector type VPU-EModel EvacuationVolumeContinuous PressureDiff erenceSuctionPortCompressed Air DimensionsTank Capacity MassPressure Consumption Supply port Out. dia. HeightVPU-E10 110N?/min 80 kPa (600 mmHG)or over. 3/8 500?600kPa・・?6kgf/cm2・・80N?/min 1/4 マ・80・・1.0・・425・・6.7・・15? 25kg/55 lbVPU-E20 220N?/min 360N?/min 3/8 マ・30・・2.9・・600・・3.6・・30? 45kg/99 lb窶サThe capacity of a compressor to use must be 2.5 kW or over for VPU-E10 and 4.5 kW or over for VPU-E20. 窶サ(1) Operating valve and (2) マ・2 hose 10 m are included as accessories.・サmm・・n・会シス笆Dry pump type VPU-D (for dry operations)窶サ(1) Operating valve, (2) マ・2 hose 10 m and (3) power cable 5 m are included as accessories.Model Evacuation Volume Continuous PressureDiff erenceSuctionPort Power SourceDimensionsTank Capacity MassWidth Length HeightVPU-D20 220/260N?/min・・0/60Hz・・80 kPa (600 mmHG) or over 3/8 3-phase 200 VAC, 0.4 kW 320・・2.6・・680・・6.7・・690・・7.1・・35? 68kg/149 lb・サmm・・n・会シス(Provide compressor.)Compressed airVacuum system(VPU-E) Operating valveVacuum chuckVacuum system(VPU-D)Operating valveVacuum chuckPiping of vacuumsystemModel VPU-EG VACUUM SYSTEMModel VPU-OV OPERATION BLOCK WITH VACUUM GAGELight weight and compact. Satisfactory functions!・サApplication・スA vacuum system dedicated to the grid seal type vacuum chucks.・サFeatures・ス笳週he vacuum tank has been eliminated to make a very compact size compared with the conventional model(VPU-E10). This system can be handled easily.笳就 function to check the vacuum status is incorporated.笳週his is for dry operation.笳就uxiliary functions in consideration of operating status and safety are incorporated. (Vacuum adjustment,interlock with the machine via vacuum check output signals, etc.)・サApplication・スAn option to facilitate the use of vacuum chucks.・サFeatures・ス笳週he operating valve and the vacuum gage have beenintegrated to enable it to check the state of workpieceholding near the chuck.笳州y changing the location of the blank cap, a position tomount the vacuum gage can be selected from three places.VPU-EGVPU-OVModel EvacuationVolumeContinuous PressureDiff erence Suction PortCompressed Air DimensionsMassPressure Consumption Supply port Out. dia. Length HeightVPU-EG 27N?/min 80 kPa (600 mmHG)or over.マ・ tube joint (Hose andvacuum coupler included)500繝シ600kPa・・繝シ6kgf/cm2・・44N?/min Vacuum coupler20PM (Nitto Kohki)200・・.87・・50・・.84・・90・・.48・・6kg/13.2 lb窶サThe capacity of a compressor to use must be around 0.75 kW.・サmm・・n・会シス(10) (10)(55) 407090(10) 70 (10)4-6.6 drill, マ・1 counterbore 8 deepマ・4Hose nipple (3/8窶・(Connected to vacuum chuck)Hose nipple (3/8窶・(Connected tovacuum chuck)90Dry/wetoperationsDry operation(Wet operation not allowed)VPU / VPU-EG / VPU-OV45 CHUCKCONTROLLERSPERMANENTMAGNETIC CHUCKSPERMANENTELECTROMAGNETIC CHUCKSBLOCKSFOR MCPROMELTA*SYSTEMSINE BARCHUCKSHOLDINGTOOLSBLOCKS, HOLDERS,MINI CHUCKSMEASURINGTOOL HOLDERSMAGNETICTOOLSMAGNETICHOLDERSELECTROMAGNETICCHUCKSVACUUM CHUCKSVACUUMCHUCKS